Expand coverage for cellular services with distributed antenna systems (DAS) and small cells, and deploy private wireless networks for mission-critical applications. That said, when a solicitation calls out that a specific component within the system must be QPL-listed, theres the distinct possibility that the contracting officer may for whatever reason simply reject it. Control: ISM-0249; Revision: 4; Updated: Dec-21; Applicability: O, P, S, TS; Essential Eight: N/ASystem owners deploying systems or military platforms overseas contact the ACSC for an emanation security threat assessment and implement any additional installation criteria derived from the threat assessment. This division enables our clients to have CATV converters, Cable Modems, Telephone Jacks, Telephone Equipment and Intercom systems installed throughout homes and offices. Arcadian Infracom and the California Department of Technology are now collaborating for a new middle-mile fiber network deployment. Visit Insights Overview to get started. Facility must be under full defence control for Active ICT to be installed. Ideally, wall outlet boxes should be the same colour that is used for associated cabling. Developing, implementing, maintaining and regularly verifying cable registers assists installers and inspectors, with the help of floor plan diagrams, to trace cables for malicious or accidental changes or damage. Article 645, Information Technology Equipment, covers the installation of information technology equipment in an information technology equipment room, i.e. Report a cyber security incident for critical infrastructure, Report a cybercrime or cyber security incident, Australian cabling standards and regulations, Security Equipment Evaluated Products List, Guidelines for Communications Infrastructure (March 2023), Guidelines for Communications Infrastructure, security control and surveillance systems. The International Standards Organization (ISO) and International Electrochemical Committee (IEC) collectively work toward establishing standards for cabling. Definitions of terms used in multiple articles in Chapter 8 have been moved to the new general article (Article 800). Fortunately, the DoDs Qualified Manufacturers List (QML) and Qualified Product List (QPL) serve this purpose and represent the gold standard for selecting acceptable products. Moreover, theyre potentially bumping up against the limits of the fabrication technologies employed to make them. . Communications Cabling - Standards Australia. Consequently, communications cables may be inadvertently spray-painted or coated with foreign substances. The ampacity of the cables, or the current rating in the case of an -LP cable, must be equal to or exceed the current rating of the power supply. We provide complete solutions to keep your small business running smoothly. Improve network capacity and enhance wireless coverage to better support indoor and outdoor data traffic demands. Failing to address emanation security threats could result in systems or military platforms emanating compromising signals, which if intercepted and analysed, could lead to serious consequences. wmR_}0d(u76(NV 5%gpu@/TTL 190 0 obj
<>/Filter/FlateDecode/ID[<67460E567C4E2643BAC2C255874CA958>]/Index[170 34]/Info 169 0 R/Length 95/Prev 165117/Root 171 0 R/Size 204/Type/XRef/W[1 2 1]>>stream
Department of Defense long-haul voice, data, and record traffic system which includes the Defense Data Network, Defense Satellite Communications System . Note, this does not necessarily mean that cables need to be fully visible all the time. Deliver optimal high-speed performance with a variety of cable assemblies, including coaxial, fiber and hybrid options. Rather, they are agreements that equipment vendors assume when developing form factors for communications interface. These notes state, respectively, Paint, plaster, cleaners, abrasives, corrosive residues, or other contaminants may result in an undetermined alteration of Class 1, Class 2, Class 3 and PLTC cable properties, and, Paint, plaster, cleaners, abrasives, corrosive residues, or other contaminants may result in an undetermined alteration of PLFA and NPLFA cable properties.. 0 G It's an ongoing commitment to progress and innovation, where our experts share research and technology that help enterprise network infrastructures perform better and more efficiently. Mission services and support. MIEE - Chapter 28 Power Control & Monitoring Systems (PCMS) MIEE 2011, Amend 3 - 1 June 2018 Chapter 28 - PCMS Page 1 of 57 . In the spirit of reconciliation the Australian Building Codes Board acknowledges the Traditional Custodians of country throughout Australia and their connections to land, sea and community. Control: ISM-0248; Revision: 6; Updated: Dec-21; Applicability: O, P; Essential Eight: N/ASystem owners deploying OFFICIAL or PROTECTED systems with Radio Frequency transmitters that will be co-located with SECRET or TOP SECRET systems contact the ACSC for an emanation security threat assessment and implement any additional installation criteria derived from the threat assessment. So, the standard now specifies continuously sweeping maximum VSWR and attenuation from 50 MHz to 11 GHz with VSWR remaining at or below 1.15:1 at 100 MHz and 1.33:1 at 11 GHz. The Defence Cabling Standard Revision Working Committee is to revise AS/CA S035:2015 Requirements for installation of temporary field telecommunications customer cabling for defence purposes Australian Standard, to: Controlling the routing from cable reticulation systems to cabinets can assist in preventing unauthorised modifications and tampering while also providing easy inspection of cables. Build high-speed networks from a variety of high-quality cable offerings that are customized to fit your needs. Control: ISM-0208; Revision: 6; Updated: Jun-21; Applicability: All; Essential Eight: N/AA cable register contains the following for each cable: Floor plan diagrams, developed using computer-aided design and drafting software, and using alphanumeric grid referencing, provide an accurate scaled view for each floor and are critical to ensuring that cabling infrastructure components can be easily located by installers and inspectors. For MIL-SPECs, this is MIL-STD-961; for MIL-STDs, it is MIL-STD-962; and for handbooks, it is MIL-STD-967. update the use of the ELV, SELV and TNV voltage levels to the new Electrical Energy Source Classifications of ES1, ES2 and ES3 specified in AS/NZS 62368.1. review and update Standards references, including AS/NZS 3000, AS/NZS 60950.1 (now superseded by AS/NZS 62368.1), AS/CA S008 and AS/CA S009. PK ! Many types of wire or cable are used in the military and defense industries. 2020 NEC Section 805.179(D) has new provisions that recognize the listing of communications Limited Power (LP) cables for these applications. In the 2020 NEC, the new Section 725.3(P) for Class 2 and Class 3 cables, and new Section 760.3(O) for power-limited fire alarm cables, permit green wires to be used ungrounded without the voltage limitations in Section 250.119. Evolve your HFC broadband networks to meet high-speed data demands as well as the need for low latency, security and increased capacity. Listed 4-pair communications cables are almost always used in place of listed 4-pair Class 2 or Class 3 cables as permitted by the Cable Substitutions Table 725.154(A). Consequently, Section 250.119 does not apply to communications circuits because that section is not referenced in Chapter 8. The current version of MIL-DTL-17 is revision J, produced in 2014. Penetrating a wall between a TOP SECRET area and a lower classified area requires the integrity of the TOP SECRET area to be maintained. 2 w The NEC has always permitted marking on communications cables to indicate additional attributes beyond those required by the Code, for example, a LAN cable marked CAT 6A. Before they were added, attenuation requirements were only specified at three frequencies, which resulted in inaccurate measurements at other frequencies. Coherent optical link achieves 200-Gbps single wavelength transmission in time for OFC, Pharma manufacturer Divis Labs taps Juniper for automated network infrastructure, Top 10 cleanest ICT cabling installs: Photos. In the 2020 NEC, Informational Notes were added to Sections 725.24 and 760.24. In such scenarios, TOP SECRET cables should be encased in conduit with all gaps between the TOP SECRET conduit and the wall filled with an appropriate sealing compound. New cabling standard, TIA-568.2-D, recognizes 28-AWG patch cords June 25, 2018 The ANSI/TIA-568.2-D standard requires de-rating of the 100-meter channel length when 28-AWG patch cords are used. In shared facilities, cables should be enclosed in a sealed cable reticulation system to prevent access and enhance cable management. 4190 0 obj
<>/Encrypt 4172 0 R/Filter/FlateDecode/ID[<7F9B1846C7D73ED6D83773510E3174B0><54F53406E92C39458E9337FDC4B282E1>]/Index[4171 48]/Info 4170 0 R/Length 98/Prev 994180/Root 4173 0 R/Size 4219/Type/XRef/W[1 3 1]>>stream
The result is that, when you partner with CommScope, you're partnering with a company that helps position your network for long-term success, with solutions that feature: Our quarterly updates on the standards relevant to the structured cabling industry, and the impact they have on your network design, planning and operations. %PDF-1.6
%
This rating relates to the complexity of the advice and information provided on the page. In the construction of office buildings, cables are often installed before construction is completed. *o2bYEPUH^vz@(\qV"iV[&Jiqqe@EuJalm{`Lwna2RnC4r|hMAYavCG+4Y=*n{(KYQB2 ?L DWlNTWgx~ As a global leader developing enterprise network solutions, we actively participate in each of our industry's major standards organizations. The text of Section 725.121(C) in the 2020 NEC states: (C) Marking. 800.27 Temperature Limitation of Wires and CablesNote that the requirement in Section 800.27 is simplified. This standard was formerly known as MIL-C-17, since it was developed in the 1940s and was revised many times over the years to better define the mechanical and electrical requirements for military coaxial cables. The requirement that the Class 2 and Class 3 circuits be classified as communications circuits conflicts with the requirement in Section 840.160 that communications circuits above 60 watts be installed in accordance with Section 725.144. Section 90.3 also exempts Chapter 8 from the requirements of Chapters 1 through 7 unless specifically referenced in Chapter 8. Standards Catalogue. RepresentativesBlulen, CISCO Systems, Comtest Laboratories, Department of Defence, Foxtel, Free TV Australia, IBM, Market Access, nbn, Optus, Telstra, TPG Telecom, Trillium Technology, Vocus, VTI Services. 7986 0 obj
<>stream
Having individual or divided cabinets can assist in preventing accidental or deliberate cross-patching and makes inspection of cables easier. The cables shall be listed as communications cables., (b) Class 2 and Class 3 Circuits. The most important and most obvious change is that Chapter 8 has a new general article. It is important to consider emanation security threats as early as possible in a systems life cycle as costs will be much greater if changes have to be made once a system has been designed and deployed. The title of the standard is Commercial Building Telecommunications Cabling Standard and is published by the Telecommunications Industry Association (TIA), a body accredited by the American National Standards Institute (ANSI).. As of 2020, the revision status of the standard is . The process for certification is daunting (Fig. Class 2 and Class 3 circuit conductors shall be permitted in the same listed communications cable with communications circuits.. Control: ISM-1640; Revision: 0; Updated: Mar-21; Applicability: All; Essential Eight: N/ACables for foreign systems installed in Australian facilities are labelled at inspection points. CHAPTER 28 . 7964 0 obj
<>/Filter/FlateDecode/ID[<19CA5B9FD300BC40A3823C87A480C8C7>]/Index[7949 38]/Info 7948 0 R/Length 81/Prev 484016/Root 7950 0 R/Size 7987/Type/XRef/W[1 2 1]>>stream
2: An example of a label is 52V @ 0.433A, 56V MAX for an IEEE 802.3 compliant Class 8 power source.. It covers the requirements for fixed or concealed cabling or equipment that is connected, or is intended to be connected, to a telecommunications network. Finally, semi-rigid or rigid cables never bend once theyre formed when manufactured. The intent of these standards is to provide recommended practices for the design and installation of cabling systems that will support a wide variety of . In certain circumstances it may not be possible to use the correct colour for SECRET or TOP SECRET cables. Nor was there any requirement for adhesion of the dielectric core to the center conductor, with the result that it was possible to pull the center conductor out of the assembly when stripping it. An enormous number of DoD standards remain in place. Stanley Kaufman, Ph.D. is principal of CableSafe Inc. and a consultant to the Communications Cable and Connectivity Association (CCCA). sC. The InterNational Committee for Information Technology Standards (INCITS) develops standards governing the security, storage, transfer and management of information. Control: ISM-0246; Revision: 4; Updated: Jun-22; Applicability: O, P, S, TS; Essential Eight: N/AAn emanation security threat assessment is sought as early as possible in a systems life cycle as implementing emanation security can have significant cost implications. These new marking requirements facilitate matching the ampacities of the cables with the output current of the power supply. hb```b```` cb
@%97g9ce]j:M5ADnnQ]5j^:g iI{^Fn3OR{@yMre`/@,vc?,bXb?IW0>qlM]2\@8uA e`\4
,H-``S(cV0 &:
hbbd``b`Z D|)1@}H6D ) Hlc`bRHko 5
Multi-source agreements (MSAs) are not official standards organizations. Information Note No.
We are a data wiring installation company that works to help customers with installation needs. Join our dynamic team of talented innovators as we redefine connectivity across the globe. S@=k)zzhL=*wJ7-/ DEPARTMENT OF ADMINISTRATION. However, an inner wall can be used to run TOP SECRET cables where sufficient space exists for their inspection. Page 2 of 32 TasNetworks Standard - Communications and Data Cabling Standard Authorisations Action Name and title Date Prepared by John Gangemi Senior Asset Strategy Engineer, Secondary Systems, Asset Strategy Its important to note that while the standards described above are likely to be encountered by designers, theyre not the only ones, as the primary standards refer to many others (such as MIL-STD-202). U.S. Department of Defense standards dont suffer from a lack of complexity. 2023 Endeavor Business Media, LLC. The Australian Security Intelligence Organisation should be consulted before any modifications are made to TOP SECRET audio secure rooms. Painting or coating of plenum cables might compromise their fire-safety properties. hVmo8+b$%tt.C Not surprisingly, there are even standards defining how standards must be formatted and how their content must be presented. Control: ISM-1822; Revision: 0; Updated: Mar-23; Applicability: All; Essential Eight: N/AWall outlet boxes for individual systems use a consistent colour. DMS supports two classes of messages: organizational messages (formal record messages) and individual messages (informal E-mail). Surveillance, detection and intelligence systems. This Standard applies to cabling products (including cable and related customer equipment) intended for connection to the customer side of the boundary of a telecommunications network. Control: ISM-1123; Revision: 3; Updated: Dec-21; Applicability: TS; Essential Eight: N/AA power distribution board with a feed from an Uninterruptible Power Supply is used to power all TOP SECRET ICT equipment. Cablers must now comply with the 2020 Wiring Rules. Standards for cables and connectors have served the defense industry well for many years and theres every reason to believe they will continue to do so. When completed, its hoped that the result will serve as a useful guide for the selection and use of RF/microwave connectors and cables. (1) Communications Cables. Copper Cabling - 4pr, 25pr, 100pr, or more Current Ethernet "category" cable standards: Cat 3, 5/5e, Cat 6, Cat 7/7a & Cat 8 Backbone & Horizontal Distribution PVC & Plenum, Outdoor, Indoor, & Riser Patch Panels & Termination Blocks Cable Trays & Raceways Wall Mount Racks & Freestanding Racks & Cabinets TasNetworks Standard Communications and Data Cabling Standard R0001043989 Version 2.0, June 2018. In fact, the DoD has the most comprehensive requirements of any government agency in the world, and technological advances, market demands and the emergence of new applications make it essential that these standards be revised, although it typically takes several years to release revisions to a standard. k}sA ~%0vrbH"i~|>U-w7\E$gHu Control: ISM-1107; Revision: 5; Updated: Dec-21; Applicability: O, P; Essential Eight: N/AOFFICIAL and PROTECTED wall outlet boxes are coloured neither salmon pink nor red. Cabling infrastructure should be installed by an endorsed cable installer to the relevant Australian Standards to ensure personnel safety and system availability. The Amendment Declaration amends the Telecommunications (Types of Cabling Work) Declaration 1997 ( the Declaration) to reflect the replacement of . This paper, provided by the Communications Cable and Connectivity Association, is offered for general information and educational purposes. MIL-DTL-17. Other advances included a stress-crack resistance test on FEP (fluorinated ethylene propylene) and PFA (perfluoroalkoxy) jacketed cables, and the use of Type II PVC (polyvinyl chloride) for jackets, replacing the earlier specification for Type 1. In addition, cable colours for other systems, such as OFFICIAL and PROTECTED systems, may use the same colour, such as blue. Control: ISM-0181; Revision: 3; Updated: Mar-21; Applicability: All; Essential Eight: N/ACabling infrastructure is installed in accordance with relevant Australian Standards, as directed by the Australian Communications and Media Authority. All rights reserved. The Telecommunications Industry Association (TIA) represents the interests of the global information and communications technology (ICT) industry. f?3-]T2j),l0/%b Control: ISM-1719; Revision: 1; Updated: Mar-23; Applicability: TS; Essential Eight: N/ATOP SECRET cables are coloured red. Perhaps the worst example of this is MIL-HDBK-216, a handbook that covers RF transmission lines and connectors that hasnt been revised since 1962 (Fig. Defence Standard Cable. Making sure your network keeps pace with evolving technologies requires a strategic investment. At CommScope we push the boundaries of communications technology to create the worlds most advanced networks. It is important that TOP SECRET systems have control over the power system to prevent denial of service by deliberate or accidental means. CommScope premium structural support solutions reinforce your structure and optimize antenna performance. This standard, which is dedicated to coaxial connectors, provides requirements and test methods for them when used with flexible and semi-rigid cables. Whats also important to remember is that even though a product may not be QPL-listed, it doesnt necessarily mean that it falls short of meeting its requirements or is in some way inferior. The defence Estate Quality Management System (http://www.defence.gov.au/im/) contains further requirements including the principles of development, zone planning, site selection, engineering requirements and environmental impact assessment and approval requirements. TIA-568-D.4, addressed coaxial cabling components. /Icon Do Defence Audio Visual Environment (DAVE) standard Patterns are available and strongly encouraged for AV functional and passive ICT design. Article 645 is written to correlate with the fire protection requirements in NFPA 75, Standard for the Fire Protection of Information Technology Equipment. Control: ISM-0216; Revision: 3; Updated: Mar-23; Applicability: TS; Essential Eight: N/ATOP SECRET patch panels are installed in individual TOP SECRET cabinets. update the requirements to reflect the requirements in the AS/CA S009:2020 customer cabling installation Standard, to ensure alignment between the two Standards. CCCA does not endorse, approve, or certify any information set forth in this paper, nor does it guarantee the accuracy, completeness, efficacy, timeliness, or correct sequencing of such information. The other option is to use Limited Power (-LP) cables and to keep the current in each conductor below the ampere limit marked on the cable. Information Note No. Prior to the 2017 edition, NFPA 75 always required active fire protection, typically sprinklers or a gaseous clean agent, in the raised floor plenum under the data center. Control: ISM-1103; Revision: 3; Updated: Dec-21; Applicability: All; Essential Eight: N/AIn TOP SECRET areas, cable reticulation systems leading into cabinets not in server rooms or communications rooms are terminated at the boundary of the cabinet. 800.21 Access to Electrical Equipment Behind Panels Designed to Allow Access, 800.26 Spread of Fire or Products of Combustion. This article, contributed on behalf of the Communications Cable and Connectivity Association (CCCA), is intended to provide the reader with a guide to the key changes in the 2020 National Electrical Code that are of interest to manufacturers, installers, distributors and users of data/comm cables. Revision E provided criteria for remedying this while also requiring all cables be manufactured and tested to meet maximum shrink-back allowance between the dielectric core and the cable jacket. Labelling cables with the correct source and destination details minimises the likelihood of cross-patching and aids in fault finding and configuration management. The cables shall be listed as communications cables.. SA & SA/SNZ. Delight your subscribers with high-performance, easy-to-use broadband, video and home networking devices for the home. In addition, wall outlet box colours for other systems, such as OFFICIAL and PROTECTED systems, may use the same colour, such as blue. Labelling cables for foreign systems in Australian facilities helps prevent unintended cross-patching of Australian and foreign systems. Audio secure rooms are designed to prevent audio conversations from being overheard. Control: ISM-0198; Revision: 3; Updated: Dec-21; Applicability: TS; Essential Eight: N/AWhen penetrating a TOP SECRET audio secure room, the Australian Security Intelligence Organisation is consulted and all directions provided are complied with. The primary purpose of the new article is to consolidate redundant requirements by placing them into one general article. %PDF-1.6
%
Control: ISM-1105; Revision: 4; Updated: Mar-23; Applicability: S, TS; Essential Eight: N/ASECRET and TOP SECRET wall outlet boxes contain exclusively SECRET or TOP SECRET cables. In some instances this results in slightly higher ampacities being permitted. Sleeves and openings for communications cabling shall be coordinated with the other consultants to determine the location, clearances from other trades, structural concerns, etc . 2oWf [Content_Types].xml ( j0EJ(eh4NDB81$14 {1l w%=^i7+-d&0A6l4L60#S Rapidly scale fiber capacity for your enterprise, MTDC, service provider or hyperscale data center. Evolve your existing infrastructure to a hybrid-fiber coaxial access network that meets your performance, time-to-market and cost requirements. |Ek(FMiCUO5KlRE>$idd 203 0 obj
<>stream
Q?+*{(dzz\ t? S*$#|a jWT8r'@lH!Pa ?l-(9/AaT;6(p/l%Bbd4BQ,W;ki"H#hk2'70\u{'>W6!YW-"$P[.CFCGiByR. Disability Discrimination Administering Agency Attorney-General's Department All rights reserved. Cables run correctly in walls allow for neater installations while maintaining separation and inspection requirements. Ensure superior protection, reliability and scalability for your indoor and outdoor networks. Each cable will form part of a structured cabling system and will need to comply with the Australian Standards associated with that system. Furthermore, the use of designated cable colours can provide an easy way to distinguish cables for SECRET and TOP SECRET systems from cables for other systems. Australian cabling standards and regulations can be obtained from the Australian Communications and Media Authority. Understanding the Increased Demand for Industrial Switches in Food and Beverage Plants, 5 For Friday: The Essential Words in Manufacturing, a Hannover Messe Homecomingand a Preview, IIoT solutions bring machine data to life to streamline and secure performance, If youre a machine builder trying to differentiate your company from the competition, you may be considering investing in Industrial Internet of Thi, Whats Abuzz in Industrial Automation: Insights from Hannover Messe, Last May in Hannover, at one of the worlds largest trade fairs, the future of industrial automation was on everyones lips.. What does that future ho, Why universal automation is a catalyst for enabling profitable machine OEM business transformation, Todays OEMs who build machines for industrial applications are at a critical crossroads. Cables meeting MIL-T-91490 may, but not always, exceed meeting MIL-DTL-17. 31&-NYejbD 8l`w+K?j:B aRYEPNu~'b07Tt)9]E7W|H[Z0@1M?7D=Zw~3xFp }=2g)#`$]bf9}FLF7j3B)/nYgR+v3A_w@'@B@ %::5::0rRP0INy+j>j&orLb? Applications include: Available unscreened (Type A), with a braid screen (Type C), with an individual braid screen (Type D) or foil screen (Type S), from 2 core to 36 core in a range of conductor sizes. Control: ISM-0250; Revision: 4; Updated: Dec-21; Applicability: All; Essential Eight: N/AICT equipment meets industry and government standards relating to electromagnetic interference/electromagnetic compatibility. We can help your company or . Protection and mission / combat systems. There are new marking requirements in Section 725.121(C) of the 2020 NEC for power supplies that are used to supply power to cables that simultaneously transmit power and signal/communicate. Utilize tools and accessories that make indoor and outdoor installations and maintenance quick and easy. Above 60 watts, Section 840.160 defers to the requirements in Section 725.144 of Article 725, Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits. Change The installation of Class 2 and Class 3 circuits in communications cables is covered in 2017 NEC Sections 725.139(D)(1) and 800.133(A)(b). Control: ISM-0187; Revision: 8; Updated: Mar-23; Applicability: S; Essential Eight: N/ASECRET cables, when bundled together or run in conduit, are run exclusively in their own individual cable bundle or conduit.
For equipment with a rated current per conductor less than 0.3 amperes, the effective date shall be January 1, 2021. Across the globe, our people and solutions are redefining connectivity, solving todays challenges and driving the innovation that will meet the needs of whats next. In the 2020 NEC, Section 840.160 has been modified to clarify that: The communications cables must be listed communications cable with the listing in accordance with Section 805.179; The communications equipment must be listed communications equipment with the listing in accordance with Section 805.170; The power source must be listed in accordance with Section 840.170(G); Listed 4-pair communications cables are permitted to substitute for Class 2 and Class 3 cables installed in accordance with Section 725.144 and with the cable substitution requirements Section 725.154(A). Control: ISM-0194; Revision: 3; Updated: Dec-21; Applicability: TS; Essential Eight: N/AIn shared facilities, a visible smear of conduit glue is used to seal all plastic conduit joints and TOP SECRET conduits connected by threaded lock nuts. The Institute of Electrical and Electronics Engineers (IEEE) is a global organization that seeks to advance innovation and technological excellence. March 30th Webinar: How Fiber Infrastructure Optimizes Delivery of Smart Municipal Services. Control: ISM-1721; Revision: 0; Updated: Dec-21; Applicability: TS; Essential Eight: N/ATOP SECRET wall outlet boxes are coloured red. Yet, specifying these products in todays robust market can still be very confusing, and the goal of this article is to provide basic information about U.S. Department of Defense (DoD) standards related to cables and connectors.